Table 4

Technical specification of measurement technology.

Parameter Sensor/transducer type Measure range Measuring signal full range Accuracy full scale
Pressure differential Δp Capacitance 0–139 kPa 4–20 mA 0.25%
Flow rate Ultrasonic transit time 0–15 l/s 4–20 mA 1%
Torque Strain gauge 0–20 Nm 0–10 VDC 0.5%
Rotational speed Inductive 0–3000 rev/min 0–10 VDC 0.25%
A/D Converter Sigma delta 0–20 mA/
0–10 V
24 bit resolution 0.05% ± 1LSB

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.

Initial download of the metrics may take a while.