Issue |
Mécanique & Industries
Volume 9, Number 5, Septembre-Octobre 2008
|
|
---|---|---|
Page(s) | 469 - 472 | |
DOI | https://doi.org/10.1051/meca/2009010 | |
Published online | 14 March 2009 |
Étude expérimentale de la remise en suspension des particules
Comparaison entre revêtement lisse et rugueux
1
Laboratoire d'Energétique, Équipe des Transferts Thermiques et
Energétique (ETTE), FST, BP 416, Tanger, Maroc
2
LEPTAB, Pôle Sciences et Technologie, Av. Michel Crépeau,
17042 La Rochelle Cedex 1, France
Auteur de correspondance : jelhij02@univ-lr.fr
Concernant la pollution particulaire des ambiances, qu'elles soient habitables ou destinées à accueillir une population parfois importante (telles que les grands halls publics, les gares ou lieux de vie), c'est essentiellement l'étude du dépôt des particules ou de leur migration dans l'air, qui a le plus souvent été traité dans la bibliographie. Pour l'instant trop peu d'études ont été consacrées aux aspects de la remise en suspension des particules car de façon générale, qu'il s'agisse d'habitations ou de grands volumes ouverts au public, les vitesses de l'air restent relativement faibles et permettent difficilement d'"arracher" les particules déposées. C'est dans cet esprit que nous avons élaboré en cellule-test, un protocole expérimental pour mettre en évidence ce phénomène. Nos expérimentations permettront une quantification de la contribution de l'activité humaine (déplacement par la marche) dans la remise en suspension de particules initialement sur le plancher. Le paramètre sur lequel nous nous sommes focalisés ici concerne la rugosité du revêtement posé au plancher (même nature mais de rugosité différente). Nos résultats permettront d'une part de caractériser le facteur humain comme une "pseudo-source" de pollution particulaire, et d'autre part, de l'inclure dans la caractérisation particulaire des ambiances.
Abstract
Particles pollution inside buildings which are designated for living or to welcome peoples (big number of persons in buildings such as big public halls or in underground stations) is a very important subject treated in bibliography for its parameters such as particles settling and airborne transport. Nowadays there is a lack of studies developed in the frame of particles suspension in air, as the air speed in big volume rooms is low and so more difficult take off the settled particles. Therefore we have developed a testing room to measure this phenomenon. Our experiments showed out the relation between the settled particles quantity that have been arisen by the human movements inside the testing room as a function of the latest and also the inside air quality as a function of the number of persons and their activities. The parameters which could be varied were: the number of persons inside the testing room and the floor materials. Our experiments took into consideration the human activities as a source of air pollution and also as a factor which influences the inside air quality.
Mots clés : Pollution / particules / dépôt / remise en suspension / revêtement du plancher
Key words: Pollution / particle / deposition / resuspension / floor materials
© AFM, EDP Sciences, 2009
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.