Open Access

Table 1

The laser parameters applied for welding.

Sample number Pulse energy (J) Frequency (Hz) Pulse time (ms) Average power (W) Heat input (J/mm)
1 4.00 50 5 200 67
2 5.50 50 5 275 92
3 7.50 50 5 375 125
4 9.00 50 5 450 150
5 10.50 50 5 575 192
6 9.50 50 3 475 158
7 9.50 50 4 475 158
8 9.50 50 5 475 158
9 9.50 50 6 475 158
10 9.50 50 7 475 158
11 9.50 40 5 380 127
12 9.50 45 5 428 143
13 9.50 50 5 475 158
14 9.50 55 5 522 174
15 9.50 60 5 570 190