Open Access
Table 5
Desirability functions specification for the performance sensitivity measures.
Design objectives ![]() |
Observation var. ![]() |
Name | Unit | Desirability functions specifications ![]() |
||||
---|---|---|---|---|---|---|---|---|
AC | d(AC) | SL | d(SL) | Objective | ||||
1) Bandwidth of variation: | Output temperature | α1 | (°C) | 1 | 0.01 | 6 | 0.9 | Minimize |
Alcoholic volume fraction | α2 | (%) | 1 | 0.01 | 4 | 0.9 | Minimize | |
Pressure | α3 | (mbar) | 10 | 0.01 | 40 | 0.9 | Minimize | |
2) Tolerance to nominal: | Output temperature | β1 | (°C) | 0.25 | 0.01 | 2.5 | 0.9 | Minimize |
Alcoholic volume fraction | β2 | (%) | 0.05 | 0.01 | 1.25 | 0.9 | Minimize | |
Pressure | β3 | (mbar) | 5 | 0.01 | 20 | 0.5 | Minimize | |
3) Minimum admissible: | Output temperature | γ1 | (°C) | 20 | 0.05 | 25 | 0.9 | Target |
35 | 0.05 | 30 | 0.9 | |||||
Alcoholic volume fraction | γ2 | (%) | 11 | 0.05 | 11.8 | 0.9 | Target | |
13 | 0.05 | 12.2 | 0.9 | |||||
Pressure | γ3 | (mbar) | 97 | 0.01 | 94 | 0.9 | Minimize |