Open Access

Table 2

Experimental data.

Pressure of vacuum cover Pa Flow regulating value reading m3/h Interstage pressure of SCSVP Pa Capacity of suction Pa.m3/s

1→2 2→3 3→4 4→5 5→outlet
861 0.70 861 2414 3602 19049 111316 19.80
508 0.34 508 2023 3365 17959 111100 9.65
293 0.18 293 1907 3317 17477 111316 5.07
178 0.05 178 1840 3200 17263 111316 1.41
96 0.015 96 1800 3371 17854 111533 0.41