Issue |
Mécanique & Industries
Volume 8, Number 1, Janvier-Février 2007
|
|
---|---|---|
Page(s) | 51 - 63 | |
DOI | https://doi.org/10.1051/meca:2007021 | |
Published online | 21 June 2007 |
Modélisation du comportement sismique du Génie Civil des installations nucléaires existantes
Non-linear modelling of existing nuclear facilities under seismic loading
CEA Saclay, DEN/DM2S/SEMT, 91191 Gif-sur-Yvette, France
Auteur de correspondance : didier.combescure@cea.fr
Reçu :
27
Février
2004
Accepté :
9
Février
2007
Dans les pays européens à sismicité modérée comme la France, la plupart des bâtiments en béton armé a été construite avant l'application des normes parasismiques modernes. En raison de l'absence de prise en compte du séisme lors de leur dimensionnement ou de la modification de l'aléa sismique, de nombreuses structures en béton armé ne respectent pas les normes actuelles sans être pour autant moins sûres. Pour des raisons de sûreté, les structures industrielles et nucléaires font l'objet de réévaluations sismiques régulières. L'application des méthodes de dimensionnement donne des résultats irréalistes et surtout peuvent occulter les points faibles de la structure. Cet article présente les modèles non-linéaires utilisés lors de réévaluations sismiques. Ces modélisations ont été appliquées à la modélisation de structures portique et de nœuds d'ossature testées sur table vibrante à Saclay et sur le mur de réaction du CCR d'Ispra.
Abstract
In the oldest industrial countries specially with moderate seismicity such as France, the main part of the building stock has been designed before the application of the modern seismic code. Because of the absence of any seismic consideration at the period of the construction or the modification of the action levels, many reinforced concrete structures do not satisfy the actual requirements without being unsafe. Due to safety reasons, the case of industrial and nuclear facilities and plants may be critical and requires detailed seismic evaluations. The application of simplified procedures used for design tends to give unrealistic results and, overall, masks the critical points for the facility safety. This paper aims at presenting some validation of non-linear modelling used for the seismic evaluation of existing nuclear facilities. The fibre type beam model used for this seismic assessment has non-linear constitutive laws for concrete, steel and anchorage/splices and non-linear behaviour in shear. This modelling approach has been applied to the modelling of R/C frame structures and beam column joints tested during several experimental campaigns performed on the shaking table at the CEA facility in Saclay and the reaction wall of the JRC Ispra.
Mots clés : Séisme / portique / béton armé / dispositions constructives / efforts tranchants / essais
Key words: Earthquake / reinforced concrete frame / detailing / shear / experimental tests
© AFM, EDP Sciences, 2007
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.