Issue |
Mechanics & Industry
Volume 21, Number 6, 2020
|
|
---|---|---|
Article Number | 618 | |
Number of page(s) | 15 | |
DOI | https://doi.org/10.1051/meca/2020093 | |
Published online | 15 December 2020 |
Regular Article
Enhancement of particle collection efficiency considering the structural interplay: particle motion characteristics analysis
1
Panjin Institute of Industrial Technology, Liaoning Key Laboratory of Chemical Additive Synthesis and Separation, Dalian University of Technology, Panjin 124221, PR China
2
State Key Laboratory of Fluorine Containing Functiona, Shandong Huaxia Shenzhou New Material Co. Ltd., Zibo 255000, PR China
3
School of Mechanical & Automotive Engineering, Qingdao University of Technology, Qingdao 266071, PR China
* e-mail: zhangxilong@qut.edu.cn
Received:
13
August
2020
Accepted:
25
November
2020
The vacuum-blowing cleaning system, utilizing positive and negative pressure mixed-delivery theory, has been adopted for the road sweeper vehicle. To enhance the solid particle separation performance and to evaluate the motion characteristics of inhaled particles under different structural parameters, the gas-solid flow in the vacuum-blowing cleaning system was investigated by using computational fluid dynamics (CFD) technology. The influence of the main structural parameters on the grade dust collection efficiency and average detention time of the inhaled particles was determined, such as suction-inlet diameter, suction-inlet inclination angle, and front baffle inclination angle. And the interplay between them was also investigated. In addition, a dust collection efficiency model was built, based on uniform design (UD) and multiple regression analysis (MRA), and subsequently verified via experiments. The results revealed that the structural parameters have significant influence on the dust collection performance. The suction-inlet diameter, front baffle inclination angle, and suction-inlet inclination angle exerted the highest, second-highest, and lowest influence, respectively. Furthermore, the interaction among structural parameters also influenced the collection performance. The highest, second-highest, and lowest levels of influence were determined for the inlet diameter/baffle inclination angle, inlet inclination angle/baffle inclination angle, and inlet diameter/inlet inclination interactions, respectively. The highest dust collection efficiency (i.e., 96.10%) and a short average detention time of particles in the chamber were realized under the following conditions: suction-inlet diameter and inclination angle: 200 mm and 110°, respectively, and front baffle inclination angle: 105°.
Key words: Road sweeper vehicle / vacuum-blowing cleaning system / CFD / particle motion characteristics / uniform design / multiple regression analysis
© AFM, EDP Sciences 2020
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.