Open Access

Table 7

Average drawing force from experimental and simulation results and analytical solution with JC parameters determined from the quasi-static tensile test.

  V (mm/s) Fexp Fana Fsim
Copper wires 3.52 3.3 200 37 696 630 622 10.6
400 75 697 613 615 11.7
600 112 698 592 609 12.7
800 150 686 573 578 15.7
3.52 3.1 200 38 925 729 740 20
400 77 951 730 743 21.8
600 115 956 732 751 21.4
Aluminum wires 3.72 3.3 200 36 490 435 454 7.34
400 72 471 427 443 5.94
600 108 470 418 427 9.14