Open Access
Table 2
Time steps in full explicit computations, with or without stiffness proportional damping matrix, and E/I simulation with time step ratio equal to 100.
Zone with impact/contact |
Zone without impact/contact |
|
---|---|---|
Full explicit without C = αKK | 1 × 10−6 s | 1 × 10−6 s |
Full explicit with C = αKK | 5 × 10−9 s | 5 × 10−9 s |
E/I (m = 100) C = αKK in implicit partition |
1 × 10−6 s | 1 × 10−4 s |