Open Access

Table 1

The condition of black water angle valve LV-0301A.

Parameters Units Condition 1 Condition 2 Condition 3
Mass flow/W kg/h 113609 162298 178528
Inlet pressure/P1 Barg 6.00 5.80 5.72
Pressure gap/Δp bar 3.43 3.20 3.12
Inlet Temp/t1 °C 164.94 163.781 163.307
Outlet Temp/t2 °C 139.88 139.88 139.59
Inlet liquid phase density/ρL1 g/m3 904.24 903.751 902.609
Inlet steam density/ρv1 kg/m3 3.526 3.566 3.666
Outlet liquid phase density/ρL2 g/m3 926.26 926.269 926.526
Outlet steam density/ρv2 kg/m3 1.958 1.958 1.933
Inlet liquid specific enthalpy/h1 kJ/kg 690.16 692.24 697.32
Inlet steam specific enthalpy/h1 kJ/kg 2761.5 2762.06 2763.29
Outlet liquid specific enthalpy/h2 kJ/kg 588.71 588.71 587.43
Outlet steam specific enthalpy/h2 kJ/kg 2733.6 2733.66 2733.27