Open Access

Table 3

Factor level table of structural parameters and experimental results.

NO. x1
Suction-inlet diameter (mm)
x2
Inclination angle of suction-inlet (°)
x3
Inclination angle of front baffle (°)
y
Average velocity of front inlet surface (m/s)
1 187 97 76 28.06
2 187 123 110 28.81
3 201 123 76 25.88
4 201 84 110 29.21
5 173 97 93 23.59
6 159 110 110 27.71
7 173 84 59 25.95
8 201 97 59 31.09
9 159 84 93 22.52
10 187 110 93 31.58
11 173 110 76 25.87
12 159 123 59 23.69